The second point: common faults and troubleshooting methods of chillers, common faults and troubleshooting methods of chillers: turn on the power switch, the chiller power indicator does not light, 1 does not install the fuse, install the appropriate fuse. 2 The power indicator is damaged and the electronic board is replaced. 3 power supply three-phase wiring error (note the auxiliary control line), check the wiring problem, turn on the power switch and the water pump switch to burn the fuse, the circuit short-circuit fault check control wire and the main power line pump rotor stuck, use a screwdriver to loosen the motor rotor (for 5 chiller below water pump failure 1 pump motor coil short, open circuit, repair motor coil or replace motor 2 pump overload protector automatically jumps off, the current limit of the protector is within the allowable range, half-pressed appropriately Reset button Compressor failure 1 Compressor coil is short, open circuit, replace matching compressor 2 Compressor overload protector automatically trips, adjust the current limit of the protector within the allowable range and press the reset button compressor Frosting 1 circulating water circulation or valve is not opened, check the water valve, all the pipelines, to ensure smooth flow, install short-circuit piping. 2 The circulating water pipeline is too small, and the diameter of the circulating water pipe is increased to ensure the normal water circulation. Temperature according to the table temperature display digital up and down 1 temperature control table damage, repair or replace the temperature control table 2 temperature line contact poor, repair or replace the temperature line 3 temperature line and temperature body is dirty, wipe the temperature body clean Icing in the circulating water tank 1 set the temperature too low to correct the set value 2 water in the water tank has no circulating water, short circuit water circulation between the chilled water outlet and the inlet 3 temperature control table out of control, replace the temperature control table high voltage fault heat dissipation The radiator is too dirty, the radiator can be cleaned, the air is not good, and the ventilation fan is not working. The wind turbine is not working. Check whether the fan motor is burnt out. Short-circuit repair or replacement of the motor high-pressure engine is damaged. Replace the high-pressure engine and the refrigerant is insufficient or the pipeline is leaking. After replenishing the refrigerant or repairing the leak, repair the vacuum, and then add the refrigerant to dissipate the heat. The radiator is dirty, the radiator valve is not opened or the opening is too small, the radiator is cleaned, and the valve is fully opened.
The third point starts and stops: Start the status button on the keyboard, then switch the unit ON/OFF switch on the bottom of the keyboard to the ON position. The unit will perform a self-test. After a second, one compressor is started. After the load is increased, another compressor is started. Once the unit is started, all the units that have not been operated automatically start and stop according to the change of the cooling load (refrigerated water supply and return water temperature).
Normal operation: The unit is in normal operation. The controller will monitor the oil pressure, motor current and other parameters of the system. Once there is a problem within a 24-hour operation period, a special person should permanently record the unit operating conditions at a fixed time interval. As long as the unit ON/OFF toggle switch under the keyboard is switched to the off position, the unit can be stopped. In order to prevent damage, even when the unit is shut down, do not cut off the unit's power supply. Fan, pump operation cooling tower The fan, cooling water pump and cold water pump are all independently controlled. Before starting the machine, confirm that the power supply is normal, no reverse phase, no phase loss. Before the pump is turned on, confirm that the valves in the pipeline are open.
Orange Enzyme Into Beauty Revitalizing Mask 2
Remove dirt and excess oil within the pores, and remove aging skin, making skin fresh and clean. Mask hydrating agent, will lock the moisture in the membrane, soften cuticles and help the skin to absorb nutrients, Mask quickly soothe the skin, eliminate fatigue and restore the skin's luster and elasticity. Pristine liquid containing plant extracts to soften skin tissue, promote skin metabolism, for dry or dehydrated skin. White Water mask can thoroughly remove dead skin cells, while having clean water and instant whitening effect, make the skin smooth and reproduce young, white and transparent.
Companies registered capital of 35 million yuan, the end of 2014 the total assets of 48.69 million yuan, including fixed assets of 37.52 million yuan. The company's existing cooperation Orange cultivation base 7043.5 acres, the company production base is located in Jiangxi County Tech Industrial Park Chu Tan industrial area, covers an area of 120 acres, it has built a standard plant 9,000 square meters, Nissan 6000 kg Orange enzymes and other liquid enzyme products. Enzyme, known as enzyme, refers to a polymer substance having biocatalytic functionality. In the catalytic reaction system an enzyme, the reactant molecules are known as substrates, enzyme substrates by catalytic conversion to another molecule. Almost all cellular activity of enzymes involved in the process are required to improve efficiency. Similar to other non-biological catalysts, enzymes chemical reactions by lowering the activation energy to accelerate the rate of the reaction, most of the enzyme catalyzed reaction rate can be increased a million times; in fact, the enzyme is to provide an activation energy needs than another low way, so that more particles to have less than the activation energy of the reaction kinetic energy, thus speeding up the reaction rate. Enzyme as a catalyst, in itself is not consumed during the reaction, it does not affect the chemical equilibrium reactions. Positive enzyme catalysis, but also a negative catalytic effect, not only to accelerate the reaction rate, but also to reduce the reaction rate. And other non-living catalysts is different, having a high degree of specificity of enzyme, only a catalytic reaction or produce a particular specific configuration.
Orange Enzyme Into Beauty Revitalizing Mask 2
Bossgoo(China)Tecgnology.(Bossgoo(China)Tecgnology) , https://www.tlqcjs.com