XLPE/PVC/Swa/PVC Armored Power Cable 0.6/1kv

Model NO.: YJV32 (copper) YJLV32 (aluminum)
Trademark: VILLE
Specification: iEC CE, ISO
Origin: Ningbo China
HS Code: 85
Model NO.: YJV32 (copper) YJLV32 (aluminum)
Trademark: VILLE
Specification: iEC CE, ISO
Origin: Ningbo China
HS Code: 85
XLPE/PVC/SWA/PVC Armored Power Cable 0.6/1kV 
Code : YJV22 (copper) YJLV22 (aluminum)Standard : IEC 60502. GB/T 12706-2002
Construction : 1-Solid or Stranded Copper Conductor2-XLPE insulation (cross-linked PE). 3-PVC Inner Sheath 4  Steel Wire Armour 
 5-PVC outer sheath
Application :Preferably for installation indoors. in cable ducts and in industrial plants or switching stations. under ground installation with additional protection where mechanical damage is unexpected. 
Technical Data : Max. operating temperature 90ºC Short circuit temperature 250ºC 
0.6/1kV 2-core steel wire Power Cable 0.6/1kV 3-core steel wire Power Cable.
XLPE/PVC/Swa/PVC Armored Power Cable 0.6/1kv


0.6/1kV 4+1-core steel wire Power Cable 0.6/1kV 3+1-core steel wire Power Cable .
0.6/1kV 5-core steel wire Power Cable 0.6/1kV 4-core steel wire Power Cable .
0.6/1kV, 2, 3-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 0.6/1kV, 3+1-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 0.6/1kV, 4-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 
XLPE/PVC/Swa/PVC Armored Power Cable 0.6/1kv
0.6/1kV, 4+1-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 0.6/1kV,5-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 
XLPE/PVC/Swa/PVC Armored Power Cable 0.6/1kv


 
Nominal  OD. of  Thickness of  Thickness of    Approx. weight 
cross-section  conductor  insulation  sheath  Approx. OD.  kg/km 
mm 2  mm  mm  mm  mm  CU  AL 
2×10  4.1  0.7  1.8  20.9  912.1  783.9 
2×16  5.1  0.7  1.8  23.0  1124  920.6 
2×25  6.4  0.9  1.8  26.4  1478  1156 
2×35  7.6  0.9  1.8  28.7  1775  1328 
2×50  5.6  1.0  1.9  25.4  1792  1231 
2×70  6.7  1.1  2.0  29.4  2543  1733 
2×95  8.1  1.1  2.1  32.4  3146  2022 
2×120  9  1.2  2.3  35.0  3746  2328 
2×150  11.7  1.4  2.4  42.6  5041  3292 
2×185  12  1.6  2.6  44.4  5835  3646 
3×10  4.1  0.7  1.8  21.7  1049  856.4 
3×16  5.1  0.7  1.8  24.0  1323  1017 
3×25  6.4  0.9  1.8  27.7  1779  1296 
3×35  7.6  0.9  1.8  30.2  2174  1504 
3×50  5.6  1.0  2.0  29.7  2433  1592 
3×70  6.7  1.1  2.1  34.6  3429  2215 
3×95  8.1  1.1  2.2  38.1  4327  2641 
3×120  9  1.2  2.3  41.3  5192  3066 
3×150  11.7  1.4  2.5  46.8  6704  4080 
3×185  12  1.6  2.7  51.0  8029  4747 
3×240  15.9  1.7  2.9  56.3  9995  5680 
3×300  17.8  1.8  3.0  61.2  12031  6618 
 
Nominal cross-section  OD. of conductor  Thickness of insulation  Thickness of sheath  Approx. OD.  Approx. weight 
kg/km 
mm 2  mm  mm  mm  mm  CU  AL 
3×10+1×6  12.6  0.7  1.8  22.4  1137  907 
10.7  0.7       
3×16+1×10  14.2  0.9  1.8  25.0  1471  1101 
10.7  0.7       
3×25+1×16  12.9  0.9  1.8  28.8  1984  1398 
9.8  0.7       
3×35+1×16  13.9  0.9  1.9  31.0  2372  1599 
10.7  0.7       
3×50+1×25  15.8  1.0  2.0  32.0  2807  1805 
10.7  0.9       
3×70+1×35  17.6  1.1  2.1  38.5  4012  2574 
12.6  0.9       
3×95+1×50  20.3  1.1  2.3  42.7  5038  3049 
14.2  1.0       
3×120+1×70  22.7  1.2  2.4  47.7  6661  4097 
15.8  1.1       
3×150+1×70  13.9  1.4  46.8  50.2  7768  4707 
10.7  1.1       
3×185+1×95  15.3  1.6  51.2  56.6  9357  5468 
12.6  1.1       
3×240+1×120  17.4  1.7  56.5  62.3  11592  6511 
14.2  1.2       
 
Nominal cross-section  OD. of conductor  Thickness of insulation  Thickness of sheath  Approx. OD.  Approx. weight 
kg/km 
mm 2  mm  mm  mm  mm  CU  AL 
4×10  4.1  0.7  1.8  23.2  1217  960.6 
4×16  5.1  0.7  1.8  25.7  1560  1153 
4×25  6.4  0.9  1.8  29.9  2132  1487 
4×35  7.6  0.9  1.8  32.9  2649  1755 
4×50  5.6  1.0  2.0  33.0  3218  2097 
4×70  6.7  1.1  2.1  38.7  4312  2692 
4×95  8.1  1.1  2.2  42.7  5468  3221 
4×120  9  1.2  2.3  47.9  7087  4252 
4×150  11.7  1.4  2.5  52.4  8469  4972 
4×185  12  1.6  2.7  57.0  10148  5771 
4×240  15.9  1.7  2.9  62.9  13238  6921 
4×300  17.8  1.8  3.0  69.1  16273  7798 

0.6/1kV, 4+1-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 0.6/1kV,5-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 
Nominal cross-section  OD. of conductor  Thickness of insulation  Thickness of sheath  Approx. OD.  Approx. weight 
kg/km 
mm 2  mm  mm  mm  mm  CU  AL 
4×10+1×6  4.1  0.7  1.8  24.0  1317  1023 
2.8  0.7       
4×16+1×10  5.1  0.7  1.8  27.0  1722  1251 
4.1  0.7       
4×25+1×16  6.4  0.9  1.8  31.5  2370  1624 
5.1  0.7       
4×35+1×16  7.6  0.9  1.9  33.9  2858  1863 
5.1  0.7       
4×50+1×25  8.3  1.0  2.1  38.3  3815  2482 
6.0  0.9       
4×70+1×35  9.8  1.1  2.3  42.9  4920  3036 
7.0  0.9       
4×95+1×50  11.5  1.1  2.5  49.0  6858  4201 
8.3  1.0       
4×120+1×70  12.9  1.2  2.6  53.5  8318  4914 
9.8  1.1       
4×150+1×70  14.5  1.4  2.7  58.2  9867  5694 
9.8  1.1       
4×185+1×95  16.0  1.6  2.9  63.9  11681  6606 
11.5  1.1       
4×240+1×120  18.3  1.7  3.2  70.9  14589  7972 
12.9  1.2       
 
Nominal cross-section  OD. of conductor  Thickness of insulation  Thickness of sheath  Approx. OD.  Approx. weight 
kg/km 
mm 2  mm  mm  mm  mm  CU  AL 
5×10  4.1  1.0  1.8  24.7  1391  1071 
5×16  5.1  1.0  1.8  27.6  1805  1296 
5×25  6.4  1.2  1.9  32.4  2501  1704 
5×35  7.6  1.2  2.0  36.5  3375  2258 
5×50  8.3  1.4  2.2  39.4  4093  2620 
5×70  9.8  1.4  2.3  44.6  5326  3244 
5×95  11.5  1.6  2.5  50.8  7432  4479 
5×120  12.9  1.6  2.7  55.7  8999  5265 
5×150  14.5  1.8  2.8  61.5  10936  6241 
5×185  16  2.0  3.0  67.2  12793  7188 
5×240  18.3  2.2  3.3  74.8  16041  8703 
5×300  20.5  2.4  3.5  83.2  20754  11332 
XLPE/PVC/SWA/PVC Armored Power Cable 0.6/1kV 
Code : YJV22 (copper) YJLV22 (aluminum)Standard : IEC 60502. GB/T 12706-2002
Construction : 1-Solid or Stranded Copper Conductor2-XLPE insulation (cross-linked PE). 3-PVC Inner Sheath 4  Steel Wire Armour 
 5-PVC outer sheath
Application :Preferably for installation indoors. in cable ducts and in industrial plants or switching stations. under ground installation with additional protection where mechanical damage is unexpected. 
Technical Data : Max. operating temperature 90ºC Short circuit temperature 250ºC 
0.6/1kV 2-core steel wire Power Cable 0.6/1kV 3-core steel wire Power Cable.
XLPE/PVC/Swa/PVC Armored Power Cable 0.6/1kv


0.6/1kV 4+1-core steel wire Power Cable 0.6/1kV 3+1-core steel wire Power Cable .
0.6/1kV 5-core steel wire Power Cable 0.6/1kV 4-core steel wire Power Cable .
0.6/1kV, 2, 3-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 0.6/1kV, 3+1-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 0.6/1kV, 4-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 
XLPE/PVC/Swa/PVC Armored Power Cable 0.6/1kv
0.6/1kV, 4+1-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 0.6/1kV,5-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 
XLPE/PVC/Swa/PVC Armored Power Cable 0.6/1kv


 
Nominal  OD. of  Thickness of  Thickness of    Approx. weight 
cross-section  conductor  insulation  sheath  Approx. OD.  kg/km 
mm 2  mm  mm  mm  mm  CU  AL 
2×10  4.1  0.7  1.8  20.9  912.1  783.9 
2×16  5.1  0.7  1.8  23.0  1124  920.6 
2×25  6.4  0.9  1.8  26.4  1478  1156 
2×35  7.6  0.9  1.8  28.7  1775  1328 
2×50  5.6  1.0  1.9  25.4  1792  1231 
2×70  6.7  1.1  2.0  29.4  2543  1733 
2×95  8.1  1.1  2.1  32.4  3146  2022 
2×120  9  1.2  2.3  35.0  3746  2328 
2×150  11.7  1.4  2.4  42.6  5041  3292 
2×185  12  1.6  2.6  44.4  5835  3646 
3×10  4.1  0.7  1.8  21.7  1049  856.4 
3×16  5.1  0.7  1.8  24.0  1323  1017 
3×25  6.4  0.9  1.8  27.7  1779  1296 
3×35  7.6  0.9  1.8  30.2  2174  1504 
3×50  5.6  1.0  2.0  29.7  2433  1592 
3×70  6.7  1.1  2.1  34.6  3429  2215 
3×95  8.1  1.1  2.2  38.1  4327  2641 
3×120  9  1.2  2.3  41.3  5192  3066 
3×150  11.7  1.4  2.5  46.8  6704  4080 
3×185  12  1.6  2.7  51.0  8029  4747 
3×240  15.9  1.7  2.9  56.3  9995  5680 
3×300  17.8  1.8  3.0  61.2  12031  6618 
 
Nominal cross-section  OD. of conductor  Thickness of insulation  Thickness of sheath  Approx. OD.  Approx. weight 
kg/km 
mm 2  mm  mm  mm  mm  CU  AL 
3×10+1×6  12.6  0.7  1.8  22.4  1137  907 
10.7  0.7       
3×16+1×10  14.2  0.9  1.8  25.0  1471  1101 
10.7  0.7       
3×25+1×16  12.9  0.9  1.8  28.8  1984  1398 
9.8  0.7       
3×35+1×16  13.9  0.9  1.9  31.0  2372  1599 
10.7  0.7       
3×50+1×25  15.8  1.0  2.0  32.0  2807  1805 
10.7  0.9       
3×70+1×35  17.6  1.1  2.1  38.5  4012  2574 
12.6  0.9       
3×95+1×50  20.3  1.1  2.3  42.7  5038  3049 
14.2  1.0       
3×120+1×70  22.7  1.2  2.4  47.7  6661  4097 
15.8  1.1       
3×150+1×70  13.9  1.4  46.8  50.2  7768  4707 
10.7  1.1       
3×185+1×95  15.3  1.6  51.2  56.6  9357  5468 
12.6  1.1       
3×240+1×120  17.4  1.7  56.5  62.3  11592  6511 
14.2  1.2       
 
Nominal cross-section  OD. of conductor  Thickness of insulation  Thickness of sheath  Approx. OD.  Approx. weight 
kg/km 
mm 2  mm  mm  mm  mm  CU  AL 
4×10  4.1  0.7  1.8  23.2  1217  960.6 
4×16  5.1  0.7  1.8  25.7  1560  1153 
4×25  6.4  0.9  1.8  29.9  2132  1487 
4×35  7.6  0.9  1.8  32.9  2649  1755 
4×50  5.6  1.0  2.0  33.0  3218  2097 
4×70  6.7  1.1  2.1  38.7  4312  2692 
4×95  8.1  1.1  2.2  42.7  5468  3221 
4×120  9  1.2  2.3  47.9  7087  4252 
4×150  11.7  1.4  2.5  52.4  8469  4972 
4×185  12  1.6  2.7  57.0  10148  5771 
4×240  15.9  1.7  2.9  62.9  13238  6921 
4×300  17.8  1.8  3.0  69.1  16273  7798 

0.6/1kV, 4+1-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 0.6/1kV,5-core XLPE Insulated Steel Wire Armored PVC Sheathed power cable YJV32,YJLV32 
Nominal cross-section  OD. of conductor  Thickness of insulation  Thickness of sheath  Approx. OD.  Approx. weight 
kg/km 
mm 2  mm  mm  mm  mm  CU  AL 
4×10+1×6  4.1  0.7  1.8  24.0  1317  1023 
2.8  0.7       
4×16+1×10  5.1  0.7  1.8  27.0  1722  1251 
4.1  0.7       
4×25+1×16  6.4  0.9  1.8  31.5  2370  1624 
5.1  0.7       
4×35+1×16  7.6  0.9  1.9  33.9  2858  1863 
5.1  0.7       
4×50+1×25  8.3  1.0  2.1  38.3  3815  2482 
6.0  0.9       
4×70+1×35  9.8  1.1  2.3  42.9  4920  3036 
7.0  0.9       
4×95+1×50  11.5  1.1  2.5  49.0  6858  4201 
8.3  1.0       
4×120+1×70  12.9  1.2  2.6  53.5  8318  4914 
9.8  1.1       
4×150+1×70  14.5  1.4  2.7  58.2  9867  5694 
9.8  1.1       
4×185+1×95  16.0  1.6  2.9  63.9  11681  6606 
11.5  1.1       
4×240+1×120  18.3  1.7  3.2  70.9  14589  7972 
12.9  1.2       
 
Nominal cross-section  OD. of conductor  Thickness of insulation  Thickness of sheath  Approx. OD.  Approx. weight 
kg/km 
mm 2  mm  mm  mm  mm  CU  AL 
5×10  4.1  1.0  1.8  24.7  1391  1071 
5×16  5.1  1.0  1.8  27.6  1805  1296 
5×25  6.4  1.2  1.9  32.4  2501  1704 
5×35  7.6  1.2  2.0  36.5  3375  2258 
5×50  8.3  1.4  2.2  39.4  4093  2620 
5×70  9.8  1.4  2.3  44.6  5326  3244 
5×95  11.5  1.6  2.5  50.8  7432  4479 
5×120  12.9  1.6  2.7  55.7  8999  5265 
5×150  14.5  1.8  2.8  61.5  10936  6241 
5×185  16  2.0  3.0  67.2  12793  7188 
5×240  18.3  2.2  3.3  74.8  16041  8703 
5×300  20.5  2.4  3.5  83.2  20754  11332 

D-Subminiature Connectors

The D-subminiature or D-sub is a common type of electrical connector. They are named for their characteristic D-shaped metal shield. When they were introduced, D-subs were among the smallest connectors used on computer systems.

A D-sub contains two or more parallel rows of pins or sockets usually surrounded by a D-shaped metal shield that provides mechanical support, ensures correct orientation, and may screen against electromagnetic interference. The part containing pin contacts is called the male connector or plug, while that containing socket contacts is called the female connector or socket. The socket's shield fits tightly inside the plug's shield. Panel mounted connectors usually have threaded nuts that accept screws on the cable end connector cover that are used for locking the connectors together and offering mechanical strain relief. Occasionally the nuts may be found on a cable end connector if it is expected to connect to another cable end. When screened cables are used, the shields are connected to the overall screens of the cables. This creates an electrically continuous screen covering the whole cable and connector system.

ANTENK offers one of the most comprehensive lines of high reliability D-Subminiature connectors available for military, avionics, space and high reliability industrial applications.


Features of ANTENK D-Subminiature Connectors


  1. Standard density d-subminiature connectors
  2. High density d-subminiature connectors, contacts are available as well as several custom and combination versions.
  3. All d-subminiature connectors may be manufactured with crimp, solder cup, straight PCB and right angle PCB terminations (except solder cup terminations on High Density configurations).





Ragne of of ANTENK D-Subminiature Connectors

Standard Density solder cup, stamped & formed contact D-subminiature connectors

High Density solder cup, stamped & formed contact D-subminiature connectors
Standard Density solder cup,machined contacts D-subminiature connectors
High Density solder cup,machined contacts D-subminiature connectors
crimp & load D-subminiature connectors
IDC D-subminiature connectors
Standard Density vertical mount D-subminiature connectors
High Density vertical mount D-subminiature connectors
Standard Density right angle D-subminiature connectors
High Density right angle D-subminiature connectors
surface mount D-subminiature connectors
Slim D-sub series
D-subminiature connectors stacked D-sub series



D-Subminiature Connectors

ShenZhen Antenk Electronics Co,Ltd , https://www.antenkconn.com