So far, the overclocked three-spot light kit has produced 30 models of three generations. Stylish and exquisite shape design, noble and classic temperament, destined to be a high-value series. However, the floodlight kit clearly depends on the value of the face, but it depends on the strength!
Floodlights are widely used in indoor and outdoor lighting in shopping malls, exhibition halls, parking lots, stadiums, billboards, buses, sculptures, and national lighting projects. When the outdoor lighting is used, the external environment is more complicated. In addition to the influence of rain and strong winds, the dust and dust factors cannot be ignored, especially the dusty weather in the northern part of the country from March to May. If the luminaire does not have the ability to withstand these natural weather for a long time, it may cause malfunction or damage to the luminaire.
Xiaobian asks the professional to carry out the dust test on the finished lamp of the floodlight. The test object is the overclocked three-projection light kit TG50-A.
First, the test method
Test according to GB-T2423.37-2006 Test L, La2 Type 2 test method.
Second, the purpose of the test
The dust TG50-A is tested for its ability to protect against dust by simulating the impact of outdoor dust on the product through a dust test chamber.
Third, the sample situation
The test sample is an assembled TG50-A finished lamp with a sample power of 50W, as shown in the following figure:
Projection lamp TG50-A sample
Fourth, the test process
1. Put 2KG dry talcum powder into the test chamber;
2. Before the product is tested, it should be placed in a normal temperature atmosphere for about 2 hours;
3. Place the sample on the shelf in the dust box (centered);
4. Set the test parameters and start the test;
5. After 8 hours, the test is completed, take a sample, turn off the power, and let stand for 2 hours to wait for sand and dust to precipitate;
6. Use a brush to clean the fine dust on the surface of the sample in the test chamber, and then take it out and blow it off with a wind gun;
7. Check that the sample is lit normally and disassemble the glass to see if it is invading the dust.
Sample status after testing
Preliminary cleanup
Five, test results
The blown TG50-A sample was energized, the sample was lit normally, and the lamp bead was not flickering. Remove the glass and visually invade without dust. As shown below:
The sample is normally lit after the test
Remove the glass
Visual inspection
Conclusion
The floodlight TG50-A is tested according to GB-T2423.37-2006 test L, La2 type 2 test method. After 8 hours of sand dust test, the sample is normally lit, the glass is opened, and no dust is entered inside the silicone ring.
In this test, it is done under laboratory conditions, considering only the effects of wind and fine sand, and there is rainwater in the actual environment, and sandstone with larger diameter will also have an effect on the product. Therefore, the test conditions and actual conditions may have slightly different effects on the product.