Oxygen index tester - Huaqiang Electronic Network

Kaixin micro test
Test - lowercase jpg
Test probe PH-5H

SYL-16 oxygen index tester


one,

Overview

SYL-16 oxygen index tester

,

It is a new model developed according to the technical requirements of the national standard GB/T2406. The instrument is used to determine the volume percentage of oxygen required during the combustion of the polymer. The polymer oxygen index value is the oxygen and nitrogen mixed gas stream required to maintain a combustion length of 50 mm or a combustion time of 180 s after ignition of the material. The minimum oxygen concentration (also known as the oxygen index) required to maintain the pattern burning.

The instrument can be used not only as a means to identify the flame retardancy of polymers, but also as a research tool, providing a powerful test method for laboratory research on flame retardant formulations and the development of new flame retardant materials. Suitable for flammability testing of materials such as solid materials, laminates, foams, fabrics, films and films.

The structure of the instrument is reasonable in design, easy to operate and maintain. The test system uses an imported oxygen sensor and displays the results numerically. It has the advantages of accurate judgment and good reproducibility. It is an ideal test equipment for scientific research and production quality control.

two,

Main Specifications

1.

Using imported oxygen sensor, the digital display shows the oxygen concentration without calculation, the accuracy is higher and more accurate, the range is 0-100%

2.

Digital resolution: ±0.1%

3.

Measurement accuracy: 0.4

4.

Flow adjustment range: 0-10L/min (60-600L/h)

5.

Response time: <5S

6.

Combustion tube: inner diameter ≥75mm high 400mm

7.

Gas flow rate in the combustion cylinder: 40mm ± 10mm / s

8.

Pressure gauge accuracy 2.5, resolution: 0.01MPa

9.

Flowmeter: 1-15L/min (60-900L/H) adjustable

10.

Oxygen/nitrogen mixed gas inlet: including pressure regulator, flow regulator, gas filter and mixing chamber.

11.

Sample holders can be used for soft and rigid plastics, textiles, fire doors, etc.

12.

Propane (butane) ignition system, flame length 5mm-60mm can be adjusted freely

13.

Gas: industrial nitrogen, oxygen, purity >99%; (user-supplied).

14.

Igniter: It has a metal tube and a nozzle with an inner diameter of Φ2±1mm at the end. It can be inserted into the combustion tube to ignite the sample.

Flame length: 16±4mm, adjustable size

15.

Self-supporting material sample holder: can be fixed at the axial position of the combustion tube and can clamp the sample vertically

16.

Non-self-supporting material sample holder: can fix two vertical sides of the sample on the frame at the same time

three,

Instrument working conditions

1.

Ambient temperature: -10 ° C ~ 45 ° C

2.

Relative humidity: <85%;

3.

Voltage and power: 220V, 50HZ, 100W

4.

Gas used: GB3863 industrial gaseous oxygen; GB3864 industrial gaseous nitrogen; both bottles of gas should be pressure regulating valve;

5.

Input pressure: 0.2-0.3MPa

6.

Working pressure: nitrogen 0.1-0.15Mpa oxygen 0.1-0.15Mpa

Operating procedure

Semiconductor Fuse And Ferrite

Fuse refers to an electric appliance that, when the current exceeds the specified value, melts the fuse and disconnects the circuit with the heat generated by itself.When the current exceeds the specified value for a period of time, the fuse melts and disconnects the circuit with the heat generated by the fuse itself.A current protector made from this principle.The fuse is widely used in high and low voltage power distribution system and control system as well as power equipment.


Ferrite is a metal oxide with ferrous magnetism.As far as electrical properties are concerned, the resistivity of ferrite is much larger than that of single metal or alloy magnetic materials, and it has higher dielectric properties.Ferrite magnetic energy also shows high permeability at high frequencies.As a result, ferrite has become a non-metallic magnetic material widely used in the field of high frequency and weak current.Due to the low ferrite magnetic energy stored in the unit volume, saturated magnetic induction strength (Bs) and low (usually only pure iron 1/3 ~ 1/5), and thus limits its higher requirements in the low-frequency magnetic energy density in the field of high voltage and high power applications.


Semiconductor Fuse and Ferrite,Fuse Cutout, Protection Fuse, Square Fuse, Fuse Link, Ceramic Fuse

YANGZHOU POSITIONING TECH CO., LTD. , https://www.yzpst.com