Detailed description of calculation methods in LED drive circuit engineering

Calculate the number of LEDs from known power sources
Example: The rated output power is 10W power supply, using the rated forward current 20mA, how many LEDs can be configured under the condition of dissipating power of 70mW? According to the above formula (that is, the integer of the obtained data)
1: For constant voltage drive mode:
Calculate the number of LEDs in series and the number of parallel branches per branch from the known output supply voltage
(1) Calculate the number of LEDs per branch
(2) Calculate the number of parallel branches
Note: The VLED values ​​vary according to the different illuminating colors. When driving the LED with a regulated power supply, in order to control the current, a series resistor is usually required.
Example: A rated output voltage is DC24V, power is 10W power supply, rated forward current is 20mA, and the power dissipation is 70mW. The rated forward voltage is 1.8V. How many LEDs can be configured? (integer of the obtained data)
It can carry 10 sets of branches, 14 circuits of LEDs connected in series for each branch, a total of 140 LEDs.
2: For constant current drive mode
Calculate the number of parallel branches and the number of each branch from the known power output current and the current value of the LED
(1) Calculate the number of branches in parallel
(2) Calculate the number of LEDs connected in series:
Example: A rated output current is DC0.35A, rated power is 10W power supply, drive dissipated power is 70mW, forward current is 0.02A LED, how can it be configured?
Parallel count circuit:
(integer of the obtained data)
Number of connections per branch: number
That is, you can bring 17 groups, each group of 8 LEDs connected in series, a total of 136 LEDs.
Line loss and line voltage drop calculation
P wire = IRV wire = IR
R wire = σ (remark: L is the wire length; S is the wire cross-sectional area; σ is the wire conductivity) can also be found in the electrician's manual.
Example: With a length of 10 meters (5 meters for each of the positive and negative wires), 24AWG copper core wire, the current is 2A, what is the power loss and line voltage drop?
Check the electrician manual to know: R wire = 0.3737W
V wire = 2 × 0.737 = 1.474V
P wire = 2 × 0.737 = 2.948W
It can be seen from the above calculations that when the line current is large, it is necessary to pay attention to selecting a suitable wire cross section, otherwise the line loss and line voltage drop are quite large.
Only by fully understanding the basic characteristics of LED and LED power supplies can we properly design and use LED light sources.

Our company is specialized in supplying Welding Torch . Quick self-lighting,Brazes/Solders,Swirl Flame,variable flame control,Tip swivels 360 degree. Generates more heat than other hand torches. Faster brazing times and less gas consumption. Long life life. 4 interlocking safety button,reliable to use,comfortable handling. Designed for Propane or MAPP.CGA600 connections .Adjustable pressure .Use with MAPP or PROPANE TANKSTypical ApplicationsUsed for Copper/ Brass Tubes Welding/Brazing.Used for Copper/ Brass Fittings or Welding/Brazing.Valve Body made of Brass.For use with 14.1-16 OZ Containers.HVAC After Market