DC500V 20ka-40ka 2 Pole DC Surge Protection Device

Model NO.: SUP2
Shape: Cuboid
Material: Ceramic
Certification: ROHS, ISO9001, CCC, CE
Brand: Suntree/OEM
DC: 1000V 500V
AC: 275V 320V 385V 420V
Ka: 5ka-100ka
Certificate: CE
Protection Class: IP40
Operating Temperature: 5°c - +50°c
Poles: 1p 2p 3p 4p
Max Working Volt: 250V AC/30V DC
Hard Wire: 4-25
Flexible Wire: 4-16
Trademark: SUNTREE/oem
Specification: CE
Origin: Zhejiang China
HS Code: 853540000
DC500V 20KA-40KA 2 pole dc surge protection device

The SUP series Surge Protection are designed to protect against lightning surge voltages in photovoltaic power supply networks.

These units must be installed in parallel on the DC networks to be protected and provide common and differential modes protection. The SUP series is available for the main operating voltages in photovoltaic: 1000 Vdc.

The use of SUP series Surge Protection is recommended at both ends of the DC power supply line (Solar panel side and inverter/converter side),

Especially if the line routing is external and long. The electrical diagram of the SUP series is based on high energy PV equipped with specific thermal disconnectors and related failure indicators.

The SUP series is made with plug-in modules to allow a fast and easy maintenance in case of failure (disconnection from the DC network).

SUP2-PV series surge protector SUP4-PV
PV DC specific (LEC 6614-1/EN 61643-11)
Pole 2 pole 3 pole
Electrical Parameter
Classifical test II II
Uoc max (V DC) 500 900
Uc (V DC) 500 1000
In(8/20)us (KA) 20 20
Imax(8/20)us (KA) 40 40
Up (KV) 2.0 3.8
Remote control and indication
Indication window
Plug-in module
Remote signal contact
Remote signal contact Max working volt 250V AC/30V DC 250V AC/30V DC
Max working amp 1A (250V/AC) 1A (250V/AC) 1A (250V/AC)
1A (30V DC) 1A (30V DC) 1A (30V DC)
Wiring & installation
Wiring capacity(mm2) Hard wire 4-25 4-25
  Flexible wire 4-16 4-16
Stripping length  10 10
Terminal screwa M5 M5
Torque(Nm) Main ciruit 3.5 3.5
Remote signal contact 0.25 0.25
Protection class All profile IP40 IP40
Connection port IP20 IP20
Installation environment No obvious shock and vibration
Altitude(m) ≤ 2000 ≤ 2000
Working temperature -3.0--+70 -3.0--+70
Relative humidity 30%-90% 30%-90%
How to install Install with H35-7.5/DIN35 stell mounting rail
Size(mm) (W*H*L) W 36 54
H 90 90
L 67.6 67.6
Weight (KG) 0.25 0.38

Nominal PV system volt 600V 100V 1200V
MCOV(UCPV) 700V DC 1170V DC 1200V DC
Max system discharge Current (8/20us) (Imax) 40KA 40KA 30KA
Volt protection leve (UP) ≤ 2.5KV ≤ 4.0KV ≤ 4.5KV
Volt protection Level at 5KA (UP) ≤ 2.0KV ≤ 3.5KV ≤ 4.0KV
Integrate fuse breaking capacity/interrupting rating 30KA/1000V DC 30KA/1000V DC 30KA/1200V DC
Technology Short-circuit interruption (SCI) overcurrent protection
Operating temperature range -40 to +80
Nominal discharge current 12.5KA
Response time (ta) <25ns
Operating state/fault indication Green (good) / Red (replace)
Mounting  35mm DIN Rail per EN 60715
Degree protection IP20
capacity 3 modules DIN 43880


DC500V 20ka-40ka 2 Pole DC Surge Protection Device
DC500V 20ka-40ka 2 Pole DC Surge Protection Device
DC500V 20ka-40ka 2 Pole DC Surge Protection Device

AC SPD
AC SPD  Class C
Max. continuous voltage Uc 275 V 320 V 420 V/ 440V
pole 1P 2P 1P+N 3P 3P+N 4P
Nominal discharge current (8/20μs) In 20 kA
Max. discharge current (8/20μs) Imax 40 kA
Lightning impulse current (10/350) [N-PE] limp ≤ 12.5 kA
Voltage protection level [L-N] Up 1.0 kV 1.5kV 1.6kV
Voltage protection level [N-PE] Up ≤ 1.2kV
Response time tA ≤ 25 ns
Max. back-up fuse 125 A gl/gG
Short-circuit withstand current 25kA/50Hz
Operating temperature range TU -40°C+80°C
Cross-sectional area (min.) 1.5 mm2 solid / flexible
Cross-sectional area (max.) 35 mm2 stranded / 25 mm2 flexible
Mounting on 35 mm DIN rail acc. To EN 60715
Degree of protection IP 20
Housing material Thermoplastic; extinguishing degree UL 94 V-0
Remote signaling contact (floating switch) Yes (optional accessory)
Switch capacity AC: 250V/0.5A; 125V/3 A
Cross-sectional area for remote signaling terminals Max. 1.5 mm2 solid / flexible


Product Model Product Model SUP1 D,C,B
The number of poles 1P , 2P , 1P+N, 3P , 3P+N, 4P
Rated working voltage Un(V) 230/400
nominal discharge current (8/20μs)kA 10 20 30 60
Max discharge current 20 40 60 100
Max Continuous Operating Voltage 275 320 440 460 275 320 420 460 275 320 420 460 275 320 420 460
Protection level <1.0 <1.4 <1.6 <1.8 <1.2 <1.6 <1.8 <2.0 <1.5 <1.8 <2.0 <2.2 <1.6 <1.8 <2.2 <2.4
Prepose fuse 25AGL 50AGL 80AGL 80AGL
Response time (ns) <25
Leak current 75% Uc 1mA <20μA
Testing classification II
Protection class IP20
Ambient temperature limited -40°C~+80°C
Material of insulation sheath PBT/PA66
Fire Retardant level UL94 VO
Installation method 35mm standard electric rail
Outside color red
Recommended fuse or breaker A 40~63
Sectional area of the linked
power line (mm )
Phase/Null line 1.5~3.5 hard wire
Ground lead 1.5~3.5 double color
Accord to standards IEC61643-1 IEC61643-21 UL1449

FAQ:
Q:  What's your warranty ?
 A: Two years

Q:  How can i trust you and your company ?
A: Suntree is a group company, we have 6 subcompanies. 
Have cooperation with 
LS, EKF the world-class companies. 
Our company over 500 employees, products pass 
CE,IEC,TUV,SAA, RCM, ROHS certificates. 


Q: What's your contact information:
A: Our address: Liushi town, Zhejiang province, China. 
Q: What's your shipment method?
A: We ship by Express, by air, by sea, by train. Normally we checked and compare, 
then provide customer the most proper shipment method.


Q: What's about MOQ?
A: First order MOQ=1pcs

Q: If i want to release order, what's the payment method you accept ? 
A: We accept T/T, Paypal, Western union, L/C.

 Q: If i want to release order, what's the process?
A: Thanks. You can send inquiry to us by made-in-china, 
or send us by email, we will reply within 24hrs.


 Thank you & Now pls send your inquiry !  ^!^ 

Hot Dip Galvanizing Steel Pole

Huayuan Lighting Co., Ltd. , http://www.jslightpoles.com