Copper or Aluminium Building and House Wire

Model NO.: house wire
Range of Application: Flame Retardant
Certification: ISO9001, CCC
Brand: Rmjt
Product Name: Flat Electrical Wire Copper Conductor PVC Insulate
Voltage: 300/300V 300/500V 450/750V
Insulation Color: Red, Black, Yellow, Blue, Green, Grey and So on
Standard: IEC, UL, BS, VDE, AS/NZS or According to You.
Conductor Class: Calss 1, Class2, Class 5, Class6
Trademark: RMJT
Transport Package: 100m/Roll or Bag
Specification: 0.3mm2~800mm2
Origin: China
HS Code: 8544492100
Model NO.: house wire
Range of Application: Flame Retardant
Certification: ISO9001, CCC
Brand: Rmjt
Product Name: Flat Electrical Wire Copper Conductor PVC Insulate
Voltage: 300/300V 300/500V 450/750V
Insulation Color: Red, Black, Yellow, Blue, Green, Grey and So on
Standard: IEC, UL, BS, VDE, AS/NZS or According to You.
Conductor Class: Calss 1, Class2, Class 5, Class6
Trademark: RMJT
Transport Package: 100m/Roll or Bag
Specification: 0.3mm2~800mm2
Origin: China
HS Code: 8544492100
                 Copper or aluminium Building and house wire 

1.Application:
These cables are used for general wiring, unenclosed, enclosed in conduit, buried direct or in underground ducts for domestic, commercial and industrial aaplications where not subject to mechanical damage.
2.Standard:
GB/T 5023-2008, BS 6004, IEC 60227, VDE ,UL
Copper or Aluminium Building and House Wire
3.Specification:
Reference No 6192y
Flat Twin

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.
2.Colors of standard:red, black, blue, white,brown, gray, green, yellow,
Size of conductor Nominal thickness of insulation mm Mean overall diameter Upper limit mm Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires no./mm
1.0 1/1.13 0.6 2.8 14
1.5 1/1.38 0.7 3.3 20
1.5 7/0.50 0.7 3.4 20
2.5 1/1.78 0.8 3.9 33
2.5 7/0.67 0.8 4.2 34
4 1/2.25 0.8 4.4 51
4 7/0.85 0.8 4.8 51
6 1/2.76 0.8 4.9 67
6 7/1.04 0.8 5.4 71
10 1/3.57 1.0 6.4 110
10 7/1.35 1.0 6.8 120
16 1/4.50 1.0 7.3 170
16 7/1.70 1.0 8.0 180
25 7/2.14 1.2 9.8 285
35 19/1.53 1.2 11.0 380
50 19/1.78 1.4 13.0 510
70 19/2.14 1.4 15.0 715
95 19/2.52 1.6 17.0 990
120 37/2.03 1.6 19.0 1230
150 37/2.25 1.8 21.0 1510
185 37/2.52 2.0 23.5 1900
240 61/2.25 2.2 26.5 2490
300 61/2.52 2.4 29.5 3050
400 61/2.85 2.6 33.5 3900
500 61/3.20 2.8 37.0 4880


450/750V PVC Insulated (Non-Sheathed) Flexible Conductor General Purpose Cables to BS 6004 
Single Core PVC Insulated

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.
2.Colors of standard:red, black, brown, gray,orange, white, violet, pink,green/yellow, yellow
Size of conductor Nominal thickness of insulation mm Mean overall diameter Upper limit mm Approx.net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires no./mm
1.0 32/0.20 0.6 3.0 16
1.5 30/0.25 0.7 3.5 21
2.5 50/0.25 0.8 4.2 33
4 56/0.30 0.8 4.8 50
6 84/0.30 0.8 6.3 70
10 80/0.40 1.0 7.6 120
16 126/0.40 1.0 8.8 175
25 196/0.40 1.2 11.0 290
35 276/0.40 1.2 12.5 400
50 396/0.40 1.4 14.5 565
70 360/0.50 1.4 17.0 770
95 475/0.50 1.6 19.0 1010
120 608/0.50 1.6 21.0 1260
150 756/0.50 1.8 23.5 1580
185 925/0.50 2.0 26.0 1900
240 1221/0.50 2.2 29.5 2500
                                        
300/500V PVC Insulated PVC Sheathed Cables to BS 6004 
Reference No 6181y
Single Core PVC Insulated and PVC Sheathed

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound
2.Core colors: red, black.Sheath color: gray or white.
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall diameter Approx.net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires mm Lower limit mm Upper limit mm
1.0 1/1.13 0.6 0.8 3.8 4.5 28
1.5 1/1.38 0.7 0.8 4.2 4.9 35
2.5 1/1.78 0.8 0.8 4.8 5.8 50
4 7/0.85 0.8 0.9 5.4 6.8 75
6 7/1.04 0.8 0.9 6.0 7.4 100
10 7/1.35 1.0 0.9 7.2 8.8 155
16 7/1.70 1.0 1.0 8.4 10.5 225
25 7/2.14 1.2 1.1 10.0 12.5 340
35 19/1.53 1.2 1.1 11.0 13.5 445


Reference No 6192y
Flat Twin

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound
2.Color of sheath:gray or white,
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires mm Lower limit mm Upper limit mm
1.0 1/1.13 0.6 0.9 4.0*6.2 4.7*7.4 55
1.5 1/1.38 0.7 0.9 4.4*7.0 5.4*8.4 70
2.5 1/1.78 0.8 1.0 5.2*8.4 6.2*9.8 105
4 7/0.85 0.8 1.0 5.6*9.6 7.2*11.5 150
6 7/1.04 0.8 1.1 6.4*10.5 8.0*13.0 205
10 7/1.35 1.0 1.2 7.8*13.0 9.6*16.0 325
16 7/1.70 1.0 1.3 9.0*15.5 11.0*18.5 465

300/500V PVC Insulated PVC Sheathed Cables to BS 6004 
Reference No 6193y
Three Core (Flat)

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.Sheathed with PVC compound
2.Core colors: red, yellow and blue(yellow in centre )Sheath colors: gray or white.
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall diameter Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires mm Lower limit mm Upper limit mm
1.0 1/1.13 0.6 0.9 4.0*8.4 4.7*9.8 77
1.5 1/1.38 0.7 0.9 4.4*9.8 5.4*11.5 100
2.5 1/1.78 0.8 1.0 5.2*11.5 6.2*13.5 150
4 7/0.85 0.8 1.1 5.8*13.5 7.4*16.5 230
6 7/1.04 0.8 1.1 6.4*15.0 8.0*18.0 300
10 7/1.35 1.0 1.2 7.8*19.0 9.6*22.5 485
16 7/1.70 1.0 1.3 9.0*22.0 11.0*26.5 700
Reference No 6242y
Flat-Twin with Bare Earth-continuity Conductor

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.Sheathed with PVC compound
2.Core colors: red and black Sheath colors:gray or white.
Size of conductor Nominal thickness of insulation mm Size of earth conductivity conductor no./mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires mm Lower limit mm Upper limit mm
1.0 1/1.13 0.6 1/1.13 0.9 4.0*7.2 4.7*8.6 70
1.5 1/1.38 0.7 1/1.13 0.9 4.4*8.2 5.4*9.6 85
2.5 1/1.78 0.8 1/1.13 1.0 5.2*9.4 6.2*11.0 120
4 7/0.85 0.8 1/1.38 1.0 5.6*10.5 7.2*13.0 175
6 7/1.04 0.8 1/1.78 1.1 6.4*12.5 8.0*15.0 240
10 7/1.35 1.0 7/0.85 1.2 7.8*15.5 9.6*19.0 390
16 7/1.70 1.0 7/1.04 1.3 9.0*18 11.0*22.0 560
300/500V PVC Insulated PVC Sheathed Cables to BS 6004 
Reference No 6243y
Three-core (Flat) with Bare
Earth-continuity Conductor

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.Sheathed with PVC compound
2.Core colors: red, yellow and blue(yellow in centre)Sheath colors: gray or white.
Size of conductor Nominal thickness of insulation mm Size of earth- conductivity conductor No/mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires mm Lower limit mm Upper limit mm
1.0 1/1.13 0.6 1/1.13 0.9 4.0*9.6 4.7*11.0 92
1.5 1/1.38 0.7 1/1.13 0.9 4.4*10.5 5.4*12.5 115
2.5 1/1.78 0.8 1/1.13 1.0 5.2*12.5 6.2*14.5 170
4 7/0.85 0.8 1/1.38 1.1 5.8*14.5 7.4*18.0 255
6 7/1.04 0.8 1/1.78 1.1 6.4*16.5 8.0*20.0 340
10 7/1.35 1.0 7/0.85 1.2 7.8*21.0 9.6*25.5 550
16 7/1.70 1.0 7/1.04 1.3 9.0*24.5 11.0*29.5 790
300/300V PVC Insulated Parallel Flexible Cords to BS 6500 
Reference No 2812X
Twin Core 

Notes
1.Conductors of high conductivity copper wires insulated with PVC compound.
2.One core with a ridge for identification
Size of conductor Nominal thickness of insulation mm Mean overall dimensions Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires no/mm Lower Limit mm Upper Limit Mm
0.5 28/0.15 0.8 2.5x5.0 3.0x6.0 24
0.75 42/0.15 0.8 2.7x5.4 3.2x6.4 29

300/500V and 450/750V PVC Insulated Flexible Cords to BS 6500/6004 
Reference No 2491X
Single Core 

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.
2.Standard colors: red.black, white, blue,brown, gray and green/yellow. 
Size of conductor Nominal thickness of insulation mm Mean overall diameter Upper limit mm Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wire no/mm
0.5 16/0.20 0.6 2.6 10
0.75 24/0.20 0.6 2.8 13
1.0 32/0.20 0.6 3.0 16
1.5* 30/0.25 0.7 3.5 20
2.5* 50/0.25 0.8 4.2 32
4.0* 56/0.30 0.8 4.8 49


300/500V PVC Insulated Twisted Twin Flexible Cords to BS 6500 
Reference No 2492X
Twisted Twin

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.
2.Two cores twisted together.
Size of conductor Nominal thickness of insulation mm Mean overall diameter of each core Upper limit mm Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires mm
0.5 16/0.20 0.6 4.6 20
0.75 24/0.20 0.6 5.0 26
1.0 32/0.20 0.6 5.4 33


300/300V PVC Insulated PVC Sheathed Parallel Twin Light Flexible Cords to BS 6500 
Reference No 2192Y
Parallel Twin

Notes
1.Conductors of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound.
2.Core colors: blue and brown Sheathed colors: gray,white or black.
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires No./mm Upper Limit mm Upper Limit mm
0.5 16/0.20 0.5 0.6 3.0x4.8 3.6x6.0 27
0.75 24/0.20 0.5 0.6 3.2x5.2 3.9x6.4 34

300/300V PVC/PVC Sheathed Circular Light Flexible Cords to BS 6500 
Reference No 2182Y
Twin Core

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound.
2.Core colors: green/ yellow blue and brown Sheathed colors: gray, white or black.Notes
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires No./mm Upper Limit mm Upper Limit mm
0.5 16/0.20 0.5 0.6 4.8 6.0 36
0.75 24/0.20 0.5 0.6 5.2 6.4 45



Reference No 2183Y
Three Core

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound. sheathed with PVC compound.
2.Core colors: green yellow blue and brown Sheathed colors: gray,white or black.
Size of conductor Nominal thickness of insulation mm Nominal thickness of Sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires no/mm Lower Limit mm Upper Limit mm
0.5 16/0.2 0.5 0.6 5.0 6.2 44
0.75 24/0.2 0.5 0.6 5.4 6.8 55

300/500V PVC/PVC Sheathed Parallel Twin Flexible Cords to BS 6500 
Reference No 3192Y
Parallel Twin

Notes
1.Conductors of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound.
2.Core colors: blue and brown Sheathed colors: gray white or black.
Size of conductor Nominal thickness of insulation mm Nominal thickness of Sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires No./mm Lower Limit mm Upper Limit mm
0.75 24/0.20 0.6 0.8 3.8*6.0 5.2*7.6 47

300/500VPVC/PVC Sheathed Circular Flexible Cords to BS 6500 
Reference No 3182Y
Twin Core 


Notes
1.Conductors of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound.
2.Core colors: blue and brown Sheathed colors:gray. white or black.
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires no/mm Lower Limit mm Upper Limit mm
0.75 24/0.20 0.6 0.8 6.0 7.6 63
1.0 32/0.20 0.6 0.8 6.4 8.0 73
1.25 40/0.20 0.7 0.8 7.0 8.6 84
1.5 30/0.25 0.7 0.8 7.4 9.0 95
2.5 50/0.25 0.8 1.0 8.9 11.0 145

300/500V PVC/PVC Sheathed Circular Flexible Cords to BS 6500 
Reference No 3183Y
Three Core


Notes
1.Conductors of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound.
2.Core colors: blue and brown Sheathed colors:gray. white or black.
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires no/mm Lower Limit mm Upper Limit mm
0.75 24/0.20 0.6 0.8 6.4 8.0 74
1.0 32/0.20 0.6 0.8 6.8 8.4 86
1.25 40/0.20 0.7 0.9 7.6 9.4 104
1.5 30/0.25 0.7 0.9 8.0 9.8 120
2.5 50/0.25 0.8 1.1 9.6 12.0 180

300/500V PVC/PVC Sheathed Circular Flexible Cords to BS 6500
Reference No 3184Y
Four Core

Notes
1.Conductors of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound.
2.Core colors: blue and brown Sheathed colors:gray. white or black.
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires no/mm Lower limit mm Upper limit mm
0.75 24/0.20 0.6 0.8 6.8 8.6 78
1.0 32/0.20 0.6 0.9 7.6 9.4 110
1. 5 30/0.25 0.7 1.0 9.0 11.0 150
2.5 50/0.25 0.8 1.1 10.5 13.0 220

Class No 802
Twin Core 


Conductors of high conductivity copper wires,Two conductors laid side by side Both insulated with PVC compound
formation,one core with a ridge for identification
Size of conductor Nominal thickness of insulation mm Nominal overall dimension mm Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires no/mm
0. 5 16/0.20 0.5 1.95*3.90 15
0.75 24/0.20 0.5 2.15*4.30 21

Class No 812
Twisted Twin

Conductors of high conductivity copper wires,insulated with PVC compound,two cores twisted together
Size of conductor Nominal thickness of insulation mm Nominal overall diameter of each core mm Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires mm
0. 5 16/0.20 0.5 1.95 16
0.75 24/0.20 0.5 2.15 22
 

4.Package:
Packing in plastic reel, paper reel ,wooden drum or as customer's requirement.
Copper or Aluminium Building and House Wire
5.Our factory:
People's Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters. 
Copper or Aluminium Building and House Wire
6.Certificate:
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
Copper or Aluminium Building and House Wire
7.Customer Visit:
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!
Copper or Aluminium Building and House Wire
8.Contact:
Dear friends, welcome to our store. We will provide you with china wholesale market market products, excellent service and reasonable price.Please contact us if have any questions about the product. we will answer the questions carefully.At last,I wish you a pleasant purchase.
Factrory ADD:No.13th,YongDing Road, Goingyi,Zhengzhou city, Henan province, China.
Tel:+86-371-55632835
Fax:+86-371-55632837
Mobile:+86-18336390736
 
 
                   Copper or aluminium Building and house wire 

1.Application:
These cables are used for general wiring, unenclosed, enclosed in conduit, buried direct or in underground ducts for domestic, commercial and industrial aaplications where not subject to mechanical damage.
2.Standard:
GB/T 5023-2008, BS 6004, IEC 60227, VDE ,UL
Copper or Aluminium Building and House Wire
3.Specification:
Reference No 6192y
Flat Twin

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.
2.Colors of standard:red, black, blue, white,brown, gray, green, yellow,
Size of conductor Nominal thickness of insulation mm Mean overall diameter Upper limit mm Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires no./mm
1.0 1/1.13 0.6 2.8 14
1.5 1/1.38 0.7 3.3 20
1.5 7/0.50 0.7 3.4 20
2.5 1/1.78 0.8 3.9 33
2.5 7/0.67 0.8 4.2 34
4 1/2.25 0.8 4.4 51
4 7/0.85 0.8 4.8 51
6 1/2.76 0.8 4.9 67
6 7/1.04 0.8 5.4 71
10 1/3.57 1.0 6.4 110
10 7/1.35 1.0 6.8 120
16 1/4.50 1.0 7.3 170
16 7/1.70 1.0 8.0 180
25 7/2.14 1.2 9.8 285
35 19/1.53 1.2 11.0 380
50 19/1.78 1.4 13.0 510
70 19/2.14 1.4 15.0 715
95 19/2.52 1.6 17.0 990
120 37/2.03 1.6 19.0 1230
150 37/2.25 1.8 21.0 1510
185 37/2.52 2.0 23.5 1900
240 61/2.25 2.2 26.5 2490
300 61/2.52 2.4 29.5 3050
400 61/2.85 2.6 33.5 3900
500 61/3.20 2.8 37.0 4880


450/750V PVC Insulated (Non-Sheathed) Flexible Conductor General Purpose Cables to BS 6004 
Single Core PVC Insulated

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.
2.Colors of standard:red, black, brown, gray,orange, white, violet, pink,green/yellow, yellow
Size of conductor Nominal thickness of insulation mm Mean overall diameter Upper limit mm Approx.net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires no./mm
1.0 32/0.20 0.6 3.0 16
1.5 30/0.25 0.7 3.5 21
2.5 50/0.25 0.8 4.2 33
4 56/0.30 0.8 4.8 50
6 84/0.30 0.8 6.3 70
10 80/0.40 1.0 7.6 120
16 126/0.40 1.0 8.8 175
25 196/0.40 1.2 11.0 290
35 276/0.40 1.2 12.5 400
50 396/0.40 1.4 14.5 565
70 360/0.50 1.4 17.0 770
95 475/0.50 1.6 19.0 1010
120 608/0.50 1.6 21.0 1260
150 756/0.50 1.8 23.5 1580
185 925/0.50 2.0 26.0 1900
240 1221/0.50 2.2 29.5 2500
                                        
300/500V PVC Insulated PVC Sheathed Cables to BS 6004 
Reference No 6181y
Single Core PVC Insulated and PVC Sheathed

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound
2.Core colors: red, black.Sheath color: gray or white.
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall diameter Approx.net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires mm Lower limit mm Upper limit mm
1.0 1/1.13 0.6 0.8 3.8 4.5 28
1.5 1/1.38 0.7 0.8 4.2 4.9 35
2.5 1/1.78 0.8 0.8 4.8 5.8 50
4 7/0.85 0.8 0.9 5.4 6.8 75
6 7/1.04 0.8 0.9 6.0 7.4 100
10 7/1.35 1.0 0.9 7.2 8.8 155
16 7/1.70 1.0 1.0 8.4 10.5 225
25 7/2.14 1.2 1.1 10.0 12.5 340
35 19/1.53 1.2 1.1 11.0 13.5 445


Reference No 6192y
Flat Twin

Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound
2.Color of sheath:gray or white,
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires mm Lower limit mm Upper limit mm
1.0 1/1.13 0.6 0.9 4.0*6.2 4.7*7.4 55
1.5 1/1.38 0.7 0.9 4.4*7.0 5.4*8.4 70
2.5 1/1.78 0.8 1.0 5.2*8.4 6.2*9.8 105
4 7/0.85 0.8 1.0 5.6*9.6 7.2*11.5 150
6 7/1

Why we recommend IPhone 6S Battery With TI IC (Texas Instruments ) rather than ZY/ZW?

1. TI IC is original method for iPhone battery .

2. Charging more faster, less fever heat to save battery life.

3. Accurate battery power monitorin

4. Keep stable performance and controlable temperture

5. The battery with TI IC more safe, charge more faster, lasts longer life.   


We are iPhone Battery manufacturer can supply Original TI IC for customer needs,iPhone 6S 0 cycle Battery with TI IC have 100% compatiable with iOS lastest system. iPhone 6S Battery TI IC is more stable performance than other IC,that is why we high recommend iPhone 6S 0 cycle battery TI IC.


iPhone 6S Battery With TI IC

iPhone 6S 0 cycle Battery with TI IC,iPhone 6S Battery TI IC,iPhone 6S 0 cycle battery TI IC

Shenzhen Aokal Technology Co., Ltd. , http://www.aokal.com